Bunney’s Inc. maintains and optimizes power-plant cooling systems across Arizona. From cooling towers and condensers to pumps, valves, and heat exchangers, we combine condition monitoring with targeted service to improve reliability, reduce energy and water use, and extend asset life.
New to Bunney’s? Learn who we are and explore our capabilities.
Why Choose Bunney’s Inc.
-
Proven power-sector expertise: Established in 1990; experience delivering complex cooling scopes on live plants—including Marley Class 700 cooling tower work at Palo Verde on an 18-day critical path. See our project portfolio.
-
Arizona-ready methods: Programs tailored for heat, dust, hard water, and monsoon season.
-
Safety & compliance: Procedures aligned with our Safety program and owner requirements.
-
End-to-end support: Inspections, chemistry control, mechanical service, repairs, and documentation—plus outage planning with your operations team.
-
Scalable service: From corrective repairs to seasonal readiness and multi-year maintenance via facility maintenance services.
What We Maintain & Test
Cooling Towers – Fill/media cleaning and replacement, drift eliminators, nozzle/distribution tuning, gearbox/motor/fan service, coatings and leak remediation. See Cooling Tower Repair & Maintenance and Cooling Tower Renovations & Repair.
Condensers & Heat Exchangers – Tube cleaning, eddy-current/IR checks (as specified), leak detection, gasket and baffle service, flow balancing.
Pumps, Motors & Drives – Alignment, vibration analysis, seal/bearing replacement, motor testing, and VFD optimization.
Valves & Piping – Packing/seat repairs, actuator calibration, flange/gasket replacement, corrosion mitigation. (See mechanical services.)
Instrumentation & Controls – Verification of temperature, flow, and level devices; alarms and interlocks testing for safe operation.
Water Chemistry & Treatment Support – Scale/corrosion/biofouling control, blowdown optimization, and documentation to protect equipment and conserve water.
Maintenance Program (What’s Included)
-
Assessment & Monitoring – Visual/IR inspections, performance trending (approach temperature, flows, vibration), and chemistry checks.
-
Preventive Tasks – Cleaning (fill/tubes), lubrication, tensioning, filter/strainer service, fastener and electrical checks.
-
Predictive Actions – Vibration and temperature trend reviews, oil/grease condition (where applicable), and early-warning findings.
-
Corrective Work – Repairs, replacements, and upgrades scheduled during outages to minimize impact.
-
Documentation – Photos, readings, test results, and recommendations for next intervals.
Planning an outage or retrofit? We phase scopes to keep generation online where possible and coordinate closely with your control room.
Arizona-Specific Considerations
-
Extreme heat: Elevates thermal load—prioritize airflow, distribution, and condenser cleanliness; verify fans/VFD settings before peak season.
-
Hard water & dust: Accelerate scaling and fouling—pair cleaning cycles with distribution tuning and drift/filtration improvements.
-
Monsoon moisture: Protect electricals, coatings, and drainage; inspect seals and louvers pre-season.
Signs Your Cooling System Needs Attention
-
Rising condenser backpressure or approach temperature
-
Increased makeup water, drift, or visible leaks
-
Fan/gearbox vibration, motor over-amps, or abnormal noise
-
Fouled fill or tubes, poor distribution, or hot spots on IR
-
Frequent chemistry alarms or uncontrolled blowdown
Industries We Support
Power generation (fossil, nuclear, renewable) • Water/wastewater utilities • Industrial campuses with central plants • Data centers and large commercial facilities